Product · Roof-Underdeck Systems
Underdeck Thermal Insulation Systems
Installed below metal roof decks to interrupt heat transfer into occupied spaces — improving indoor comfort, reducing radiant temperatures and cutting cooling loads in industrial and commercial buildings.

Overview
Stop the Heat at the Roof, Not at the Chiller
Clima Tech underdeck insulation systems install below metal roof decks to reduce heat transfer into occupied spaces, improving comfort and cutting cooling loads.
In large-span industrial and commercial buildings the roof is usually the single largest exposed surface, and an uninsulated metal deck is a very efficient conductor. On a hot afternoon it radiates downward into the space continuously — which is why occupants often report discomfort even when the air temperature reading looks acceptable. Radiant temperature, not just air temperature, is what people feel.
Treating the roof is almost always cheaper than sizing the cooling plant to overcome it.
Systems use PUF or PIR insulation from 20 mm to 100 mm, with aluminium foil, PPGI or tissue facing options, fixed mechanically or with adhesive assistance to suit the deck and the internal finish required.
Key Benefits
What Underdeck Insulation Changes
Reduced Roof Heat Gain
An effective thermal barrier between the hot roof and the occupied space below.
Improved Indoor Comfort
Lower radiant temperatures and more stable internal conditions through the working day.
Lower Cooling Demand
Reduced HVAC load, contributing directly to building energy efficiency.
Neat & Lightweight
A clean internal appearance with minimal structural load added to the roof.
Condensation Control
Foil-faced systems add vapour resistance at the underside of the deck, helping manage condensation risk where warm moist air meets a cold surface.
Plant Sizing Headroom
Cutting roof heat gain reduces the peak load the cooling system has to meet, which can influence equipment selection on new projects.
Straightforward Installation
Mechanically fixed or adhesive-assisted, working with the existing deck profile and around services already in place.
Technical Data
Reference Specification
| Parameter | Reference Value / Description |
|---|---|
| Insulation material | PUF / PIR |
| Thickness range | 20 mm to 100 mm |
| Facing options | Aluminium foil / PPGI / tissue |
| Installation method | Mechanical fixing or adhesive-assisted |
| Fire performance | Subject to approved test certification |
All configurations must be confirmed based on project-specific conditions.
Typical Applications
Where It Makes the Most Difference
- Industrial sheds and warehouses — large roof area relative to floor area, often lightly conditioned
- Manufacturing plants — where process heat already loads the space and roof gain compounds it
- Commercial buildings — top floors under metal roofs that run consistently warmer than the rest of the building
- Large-span roof structures — where the deck dominates the thermal envelope

Calculated Data
How Much Resistance Each Thickness Buys
Underdeck systems are available with a PUF or PIR core. The choice of core and the thickness together determine the resistance added to the roof.
| Core thickness | R with PIR core λ 0.020 W/m·K |
R with PUF core λ 0.023 W/mK |
U (PIR core) |
|---|---|---|---|
| 20 mm | 1.00 | 0.87 | 1.00 |
| 25 mm | 1.25 | 1.09 | 0.80 |
| 40 mm | 2.00 | 1.74 | 0.50 |
| 50 mm | 2.50 | 2.17 | 0.40 |
| 75 mm | 3.75 | 3.26 | 0.27 |
| 100 mm | 5.00 | 4.35 | 0.20 |
Insulation layer only, calculated as R = thickness ÷ λ. The actual improvement to a roof depends on the existing deck construction, air films and any ventilated cavity — we will assess your roof rather than quote a generic figure.
Why we will not quote a payback figure
Energy savings from roof insulation depend on the existing construction, the roof area relative to the conditioned volume, occupancy hours, the cooling system and local climate. Any generic percentage would be guesswork. Send us the roof details and the building’s operating pattern and we will discuss what is realistic for that specific building.
Underdeck Insulation FAQs
What does underdeck insulation actually do?
A metal roof deck in Indian conditions can reach surface temperatures far above ambient. That heat radiates and conducts into the space below, raising internal surface temperatures and adding directly to the cooling load. Underdeck insulation places a low-conductivity layer immediately beneath the deck so most of that heat is intercepted before it reaches the occupied volume.
How is it fixed?
Either by mechanical fixing or with adhesive assistance, depending on the deck profile, the panel type and the internal appearance required. The installation method is confirmed for each project during technical coordination.
Which facing should I choose?
Aluminium foil is the usual choice where a reflective, vapour-resistant face is wanted. PPGI gives a durable, coloured finish where the underside is visible and needs to look finished. Tissue facing is used where a lighter, more economical surface is acceptable.
Can it be retrofitted to an existing building?
Underdeck systems are frequently used on existing industrial and commercial buildings where cooling loads or internal comfort have become a problem. Feasibility depends on deck type, access and services already fixed below the roof — send us photographs and roof details and we will advise.
What thickness do I need?
Thickness ranges from 20 mm to 100 mm. The right figure depends on roof construction, internal conditions, occupancy and how the building is cooled. We will make a recommendation against your specific project conditions rather than quoting a default.