Product · PUF Sandwich Panels
Insulated Wall Panel Systems
Sandwich panels with a rigid polyurethane foam core bonded between protective metal facings — for rapid, modular and thermally efficient wall and partition construction from 20 mm to 100 mm thick.
Overview
A Wall That Arrives Already Insulated
Clima Tech insulated wall panels are sandwich panel systems with rigid polyurethane foam insulation bonded between protective metal facings — designed for rapid, modular and thermally efficient wall construction.
The value is in what the panel removes from the programme. A built-up wall needs a frame, a sheeting layer, an insulation layer, a vapour control layer and an internal lining, each with its own trade, delivery and inspection. A sandwich panel delivers all of that as one factory-made component, fixed in a single operation and finished on both faces the moment it is in place.
Fewer layers on site means fewer interfaces — and interfaces are where thermal continuity and weather-tightness are usually lost.
Panels are available from 20 mm to 100 mm core thickness with PPGI or GI facings, and are joined by tongue-and-groove interlocking profiles that keep the core continuous across the joint.

Panel Construction
Four Elements, One Component
- PUF core — 20 mm to 100 mm
- Rigid closed-cell polyurethane foam, chemically bonded to both facings during manufacture so the panel behaves as a composite rather than as three loose layers.
- PPGI or GI protective metal facing
- Pre-painted or plain galvanised steel on both faces, giving the panel its structural stiffness, its weather resistance and its finished appearance.
- Tongue-and-groove interlocking joints
- Male and female edge profiles that align panels during erection, close the joint and maintain insulation continuity from panel to panel.
- Project-specific finish and profile options
- Facing colour, surface profile and panel module can be selected to suit the elevation design and the fixing arrangement.

Why Sandwich Panels
Built for Speed and Thermal Performance
Rapid Erection
Modular panels install quickly with minimal wet trades on site, compressing the envelope programme.
Thermal Efficiency
A low-conductivity PUF core (≤ 0.023 W/mK) reduces heat transfer through the envelope in both directions.
Interlocking Joints
Tongue-and-groove profiles give insulation continuity across the wall and a consistent joint line.
Protective Facings
PPGI or GI facings resist corrosion, handle site conditions and arrive finished on both sides.
Low Dead Load
Light relative to masonry, which can reduce foundation and frame demands on the structure.
Closed-Cell Core
Closed-cell foam limits moisture absorption compared with open-cell or fibrous alternatives.
Simple Detailing
Standard flashings and trims close corners, openings and junctions with repeatable details.
Less Site Waste
Factory-cut modules reduce off-cuts and packaging waste compared with built-up construction.
Technical Data
Indicative Specification
| Parameter | Value |
|---|---|
| Core material | Polyurethane foam / PUF |
| Panel thickness | 20 mm to 100 mm |
| Thermal conductivity | ≤ 0.023 W/mK |
| Facing material | PPGI / GI |
| Jointing system | Tongue-and-groove interlocking |
Values indicative — validate through approved engineering data. Fire performance is subject to approved test certification for the specific panel configuration.
Where They Are Used
Key Applications
Industrial Buildings & Warehouses
Large-area envelopes where erection speed, span capability and thermal performance all bear on cost. Panels go on directly against the portal frame.
Commercial Structures & Utility Areas
Plant rooms, service blocks, back-of-house and ancillary structures needing a finished, insulated enclosure without a wet-trade programme.
Internal Partitions & HVAC Enclosures
Self-finished partitions and equipment enclosures, including temperature-separated zones and AHU rooms.
Infrastructure & Institutional Projects
Institutional and infrastructure buildings where a modular, repeatable envelope suits a fast-track programme.
Calculated Data
Choosing a Core Thickness
Core thickness is the main lever you have over envelope performance. Because thermal resistance is thickness divided by conductivity, the relationship is linear — doubling the core doubles the resistance.
| Core thickness | Minimum R (m²K/W) | Maximum U (W/m²K) | R-value (imperial) |
|---|---|---|---|
| 20 mm | 0.87 | 1.15 | 4.94 |
| 30 mm | 1.30 | 0.77 | 7.41 |
| 40 mm | 1.74 | 0.57 | 9.87 |
| 50 mm | 2.17 | 0.46 | 12.34 |
| 60 mm | 2.61 | 0.38 | 14.81 |
| 80 mm | 3.48 | 0.29 | 19.75 |
| 100 mm | 4.35 | 0.23 | 24.69 |
Because the published conductivity is a maximum (≤ 0.023 W/mK), the resistances above are minimums. Core layer only — facings, fixings and surface resistances excluded.
Core layer only
These figures describe the PUF core in isolation. A complete wall also involves the metal facings, fixings, joints, junctions and surface resistances — all of which affect the assembly’s real U-value. Treat the table as a way to compare thicknesses, and let us run the selection against your actual design condition.
Insulated Wall Panel FAQs
What thicknesses are available?
Our PUF-core insulated wall panels are manufactured from 20 mm up to 100 mm. Thickness is selected against the thermal performance the design calls for, the span between supports and the internal temperature the building has to hold.
What is the difference between PPGI and GI facings?
GI is galvanised steel; PPGI is pre-painted galvanised steel, which adds a factory-applied coating system over the zinc layer. PPGI gives a finished, coloured surface with better corrosion resistance and is normally chosen for visible external elevations. GI is common where the panel is concealed or will be finished separately.
How do the panels join?
Panels use a tongue-and-groove interlocking joint. The profile aligns adjacent panels, keeps the insulation core continuous across the joint and reduces the thermal short-circuit you would otherwise get at every panel edge.
Can panels be used for internal partitions?
Yes. Internal partitions, HVAC and plant enclosures, cold-side separations and utility areas are all common uses. Because the panels are self-finished on both faces, a partition goes up quickly without separate lining, insulating and finishing trades.
What is the fire performance?
Fire performance is subject to approved test certification for the specific panel configuration. We will issue the relevant documentation with your submittal — please confirm the required classification early so the right configuration is quoted.
Related Pages
Planning an Insulated Envelope?
Send us elevations, spans and the internal conditions you need to hold. We will recommend core thickness, facing and jointing to suit.