Product · PUF Sandwich Panels

Insulated Wall Panel Systems

Sandwich panels with a rigid polyurethane foam core bonded between protective metal facings — for rapid, modular and thermally efficient wall and partition construction from 20 mm to 100 mm thick.

Overview

A Wall That Arrives Already Insulated

Clima Tech insulated wall panels are sandwich panel systems with rigid polyurethane foam insulation bonded between protective metal facings — designed for rapid, modular and thermally efficient wall construction.

The value is in what the panel removes from the programme. A built-up wall needs a frame, a sheeting layer, an insulation layer, a vapour control layer and an internal lining, each with its own trade, delivery and inspection. A sandwich panel delivers all of that as one factory-made component, fixed in a single operation and finished on both faces the moment it is in place.

Fewer layers on site means fewer interfaces — and interfaces are where thermal continuity and weather-tightness are usually lost.

Panels are available from 20 mm to 100 mm core thickness with PPGI or GI facings, and are joined by tongue-and-groove interlocking profiles that keep the core continuous across the joint.

Completed industrial building clad in Clima Tech insulated sandwich wall panels
Insulated panel envelope on an industrial building — structure, insulation and finish delivered as one system.
20–100 mm
Core thickness range
≤ 0.023 W/mK
Thermal conductivity
PPGI / GI
Facing options
Tongue & Groove
Interlocking joint

Panel Construction

Four Elements, One Component

PUF core — 20 mm to 100 mm
Rigid closed-cell polyurethane foam, chemically bonded to both facings during manufacture so the panel behaves as a composite rather than as three loose layers.
PPGI or GI protective metal facing
Pre-painted or plain galvanised steel on both faces, giving the panel its structural stiffness, its weather resistance and its finished appearance.
Tongue-and-groove interlocking joints
Male and female edge profiles that align panels during erection, close the joint and maintain insulation continuity from panel to panel.
Project-specific finish and profile options
Facing colour, surface profile and panel module can be selected to suit the elevation design and the fixing arrangement.
Insulated wall panel lifted into place, with stacked panels staged below
Panels are erected directly onto the frame — no separate insulation or lining trade follows behind.

Why Sandwich Panels

Built for Speed and Thermal Performance

Rapid Erection

Modular panels install quickly with minimal wet trades on site, compressing the envelope programme.

Thermal Efficiency

A low-conductivity PUF core (≤ 0.023 W/mK) reduces heat transfer through the envelope in both directions.

Interlocking Joints

Tongue-and-groove profiles give insulation continuity across the wall and a consistent joint line.

Protective Facings

PPGI or GI facings resist corrosion, handle site conditions and arrive finished on both sides.

Low Dead Load

Light relative to masonry, which can reduce foundation and frame demands on the structure.

Closed-Cell Core

Closed-cell foam limits moisture absorption compared with open-cell or fibrous alternatives.

Simple Detailing

Standard flashings and trims close corners, openings and junctions with repeatable details.

Less Site Waste

Factory-cut modules reduce off-cuts and packaging waste compared with built-up construction.

Technical Data

Indicative Specification

Insulated wall panel — indicative properties
ParameterValue
Core materialPolyurethane foam / PUF
Panel thickness20 mm to 100 mm
Thermal conductivity≤ 0.023 W/mK
Facing materialPPGI / GI
Jointing systemTongue-and-groove interlocking

Values indicative — validate through approved engineering data. Fire performance is subject to approved test certification for the specific panel configuration.

Where They Are Used

Key Applications

Industrial Buildings & Warehouses

Large-area envelopes where erection speed, span capability and thermal performance all bear on cost. Panels go on directly against the portal frame.

Commercial Structures & Utility Areas

Plant rooms, service blocks, back-of-house and ancillary structures needing a finished, insulated enclosure without a wet-trade programme.

Internal Partitions & HVAC Enclosures

Self-finished partitions and equipment enclosures, including temperature-separated zones and AHU rooms.

Infrastructure & Institutional Projects

Institutional and infrastructure buildings where a modular, repeatable envelope suits a fast-track programme.

See all sectors we serve

Calculated Data

Choosing a Core Thickness

Core thickness is the main lever you have over envelope performance. Because thermal resistance is thickness divided by conductivity, the relationship is linear — doubling the core doubles the resistance.

Wall panel thermal resistance by core thickness

Minimum R-value of the PUF core at ≤ 0.023 W/mK. Doubling the core doubles the resistance.

20 mm core
0.87
30 mm core
1.30
40 mm core
1.74
50 mm core
2.17
60 mm core
2.61
80 mm core
3.48
100 mm core
4.35
R-value in m²K/W · bars scaled to the largest value
Insulated wall panels — calculated thermal resistance (λ ≤ 0.023 W/mK)
Core thickness Minimum R (m²K/W) Maximum U (W/m²K) R-value (imperial)
20 mm0.871.154.94
30 mm1.300.777.41
40 mm1.740.579.87
50 mm2.170.4612.34
60 mm2.610.3814.81
80 mm3.480.2919.75
100 mm4.350.2324.69

Because the published conductivity is a maximum (≤ 0.023 W/mK), the resistances above are minimums. Core layer only — facings, fixings and surface resistances excluded.

Core layer only

These figures describe the PUF core in isolation. A complete wall also involves the metal facings, fixings, joints, junctions and surface resistances — all of which affect the assembly’s real U-value. Treat the table as a way to compare thicknesses, and let us run the selection against your actual design condition.

Insulated Wall Panel FAQs

What thicknesses are available?

Our PUF-core insulated wall panels are manufactured from 20 mm up to 100 mm. Thickness is selected against the thermal performance the design calls for, the span between supports and the internal temperature the building has to hold.

What is the difference between PPGI and GI facings?

GI is galvanised steel; PPGI is pre-painted galvanised steel, which adds a factory-applied coating system over the zinc layer. PPGI gives a finished, coloured surface with better corrosion resistance and is normally chosen for visible external elevations. GI is common where the panel is concealed or will be finished separately.

How do the panels join?

Panels use a tongue-and-groove interlocking joint. The profile aligns adjacent panels, keeps the insulation core continuous across the joint and reduces the thermal short-circuit you would otherwise get at every panel edge.

Can panels be used for internal partitions?

Yes. Internal partitions, HVAC and plant enclosures, cold-side separations and utility areas are all common uses. Because the panels are self-finished on both faces, a partition goes up quickly without separate lining, insulating and finishing trades.

What is the fire performance?

Fire performance is subject to approved test certification for the specific panel configuration. We will issue the relevant documentation with your submittal — please confirm the required classification early so the right configuration is quoted.

Planning an Insulated Envelope?

Send us elevations, spans and the internal conditions you need to hold. We will recommend core thickness, facing and jointing to suit.